Many tips are given in the document Server Messages and Error Codes, especially in Chapter 4. Descriptions of I/O codes in server messages or in the Problem Determination Guide ISP7.1.0 or Problem Determination Guide ISP8.1.0
This page will move to the Operational Documentation of SP at GWDG
trying to remove a replication server fails:
Protect: SM286>del server SM287 ANR1664W DELETE SERVER: Server SM287 is currently in use. ANS8001I Return code 12.
ToDo:
REMove REPLnode <NODENAME> SERVER=<Name of Replicationserver>
SET REPLServer <nothing!>
Trying to remove a replication relationship from a node fails like this
ANR3443W When the REMOVE REPLNODE command was run, one or more nodes (KOPAL-TEST) were skipped because they are not configured to replicate data to the specified server SM287. ANR3445I If a node has no replication associations with any servers, you must specify an empty string (server="") for the SERVER parameter for the REMOVE REPLNODE command to reset a node's replication state. If the node has a replication association with one or more servers, you must specify a valid target replication server name. ANR1632E REMOVE REPLNODE: Command failed. Replication state information for the specified nodes could not be removed.
Workround:
REMove REPLNode <nodename> REPLServer=''
“KEY = 05” means Problems accessing Drive
in relation with
ASC/ASCQ | Meaning | Source |
---|---|---|
ASC=26 , ASCQ=00 + ANR8533W | Due to the 'CHECKTAPEPOS' setting ISP is unable to set the drive to 'APPENDONLY' | IBM-Documentation |
“KEY = 06” means “Unit Attention”
in relation with
ASC/ASCQ | Meaning | Source |
---|---|---|
ASC=2A, ASCQ=03 | SCSI reservation error because several TSM instances use the same persisten name | https://www-01.ibm.com/support/docview.wss?uid=swg1IT03879 |
ASC=29 , ASCQ=00 | “Power-on, reset, bus reset” | https://www-01.ibm.com/support/docview.wss?uid=swg1IT20573 |
ANR8460E AUDIT LIBRARY process for library <Library Name> failed.
in combination with | possible reason | solution |
---|---|---|
ANR9024E There are no drives available. | at least one drive is not available | check drives and make all available |
check if drives are rotten and if so, remove their definition and paths completely |
PVRRC | Meaning | Source | Solution |
---|---|---|---|
2843 | unable to access gripper device | – | restart Lintape daemon or Wintape service |
PVRRC | Meaning | Source | Solution |
---|---|---|---|
2845 | Unable to open device <DEVICE> | audit library failed after drives / paths got unavailable | scsi information mismatch: |
* reboot server | |||
* reboot library | |||
* force rescan scsi bus on device layer | |||
* check if the lintape driver is running |
ANR 8779E Unable to open drive <NAME>, error number= 2
in combination with
ANR1401W Mount request denied for volume <NAME> - mount failed.
Possible Reasons:
rescan-scsi-bus.sh
udevadm trigger